Gold Testing Method

Atomic Absorption Spectrometry (AAS)

Targeted Quantitative Element Determination

Atomic Absorption Spectrometry (AAS) is an instrumental technique used to quantitatively determine selected elements in an appropriately prepared sample.

It is a targeted analytical approach rather than a surface scanner or a non-destructive test for an intact bullion bar.

Bilex reviews the sample, requested element and intended use before confirming method availability and preparation requirements.

Bilex Sample Handling
Identified gold samples prepared for instrumental analysis at Bilex Minerals EA.
Identified gold samples recorded before instrumental analysis.

What Is AAS?

AAS measures the absorption of light at wavelengths characteristic of specific elements. The amount of absorbed light is related to the concentration of the selected element under the applicable analytical procedure.

The technique normally focuses on selected target elements. It requires the analytical portion to be prepared in a suitable form before measurement and should not be described as a gold scanner, a surface test or a universal replacement for Fire Assay.

In suitable analytical workflows, AAS may be used as an instrumental finish after an appropriate precious-metal collection procedure. This means AAS and Fire Assay are not necessarily mutually exclusive stages.

Applications

Where Atomic Absorption Spectrometry (AAS) Is Used

Targeted Determination

Quantify a selected element where the sample form, concentration and procedure are suitable.

Gold-Bearing Material

Analyse an appropriately prepared portion of ore, concentrate or other suitable material.

Refinery Samples

Support focused analysis of identified and suitably prepared refinery or process samples.

Doré-Derived Samples

Measure selected elements in a representative prepared sample when the procedure is appropriate.

Analytical Finish

Serve as an instrumental measurement finish in certain Fire Assay workflows.

Suitable material

Materials and Sample Forms

  • Prepared gold-bearing ore
  • Prepared concentrates
  • Refinery and process samples
  • Suitable doré-derived analytical samples
  • Other appropriately prepared gold-bearing material

Before testing

Sample Requirements

  • AAS requires an appropriately prepared analytical sample rather than direct measurement of an intact bullion item.
  • The target element, expected concentration, material matrix and selected AAS approach affect suitability.
  • Sampling must connect the analytical portion to the defined material if the result is intended to represent a larger lot.
  • Exact sample quantity, preparation and reporting scope are confirmed for the specific enquiry.

Process

From Testing Question to Report

  1. Define the Question

    Describe the material, the result you need and how the information will be used.

  2. Review Suitability

    Bilex reviews the sample form, expected composition, required analytes and any restriction on alteration.

  3. Agree the Scope

    The method, representative sampling relationship, preparation requirements and reporting scope are confirmed before work begins.

  4. Prepare & Analyse

    An identified analytical sample is prepared and measured according to the applicable confirmed procedure.

  5. Review the Result

    The reported result is interpreted within the method, sample identity and limitations stated for the work.

What it contributes

Strengths

  • Focused quantitative determination of selected elements
  • Useful where a targeted analytical question is clearly defined
  • Can be applied after suitable preparation
  • May be used as an instrumental finish in an appropriate Fire Assay workflow

Scope

Limitations to Understand

  • Usually targeted rather than broad simultaneous multi-element analysis
  • Requires sampling and preparation
  • Does not provide a non-destructive intact-bar reading
  • Suitability depends on matrix, concentration and validated scope
  • Does not automatically replace Fire Assay or representative sampling

Method selection

How This Method Relates to Other Tests

AAS vs ICP-OES

AAS commonly targets selected individual elements. ICP-OES can measure multiple selected elements during a multi-element run.

The appropriate technique depends on the sample matrix, expected concentration, required analytes, analytical procedure and reporting requirement—not on a claim that one instrument is always superior.

AAS vs XRF and Fire Assay

XRF provides rapid surface-region elemental information from a suitable item. AAS provides quantitative measurement from an appropriately prepared analytical sample.

Fire Assay is a precious-metal collection and separation procedure. AAS may be used as a measurement finish after suitable Fire Assay collection, so the two terms can describe different parts of one workflow.

View all testing methods

Questions

Frequently Asked Questions

What does AAS measure?

AAS measures the concentration of a selected element in an appropriately prepared analytical sample by measuring characteristic light absorption.

Can AAS determine gold?

It can determine gold when the preparation, concentration range, calibration and analytical procedure are suitable for the sample and intended result.

Does AAS require sample preparation?

Yes. AAS is not a direct intact-bar scanner. The analytical portion must be prepared in a form appropriate to the confirmed procedure.

Can AAS be used after Fire Assay?

Yes, AAS can serve as an instrumental finish after an appropriate precious-metal collection procedure in certain analytical workflows.

How does AAS differ from ICP-OES?

AAS is commonly used for selected target elements, while ICP-OES can measure multiple selected elements in one analytical run. Method suitability depends on the specific sample and requirement.

Discuss the sample

Discuss AAS Analysis

Tell us the material, available sample quantity and the information the result needs to establish.

The final method and sample requirements are confirmed after the material and testing objective have been reviewed.

Discuss AAS Analysis