Targeted Determination
Quantify a selected element where the sample form, concentration and procedure are suitable.
Gold Testing Method
Targeted Quantitative Element Determination
Atomic Absorption Spectrometry (AAS) is an instrumental technique used to quantitatively determine selected elements in an appropriately prepared sample.
It is a targeted analytical approach rather than a surface scanner or a non-destructive test for an intact bullion bar.
Bilex reviews the sample, requested element and intended use before confirming method availability and preparation requirements.

AAS measures the absorption of light at wavelengths characteristic of specific elements. The amount of absorbed light is related to the concentration of the selected element under the applicable analytical procedure.
The technique normally focuses on selected target elements. It requires the analytical portion to be prepared in a suitable form before measurement and should not be described as a gold scanner, a surface test or a universal replacement for Fire Assay.
In suitable analytical workflows, AAS may be used as an instrumental finish after an appropriate precious-metal collection procedure. This means AAS and Fire Assay are not necessarily mutually exclusive stages.
Applications
Quantify a selected element where the sample form, concentration and procedure are suitable.
Analyse an appropriately prepared portion of ore, concentrate or other suitable material.
Support focused analysis of identified and suitably prepared refinery or process samples.
Measure selected elements in a representative prepared sample when the procedure is appropriate.
Serve as an instrumental measurement finish in certain Fire Assay workflows.
Suitable material
Before testing
Process
Describe the material, the result you need and how the information will be used.
Bilex reviews the sample form, expected composition, required analytes and any restriction on alteration.
The method, representative sampling relationship, preparation requirements and reporting scope are confirmed before work begins.
An identified analytical sample is prepared and measured according to the applicable confirmed procedure.
The reported result is interpreted within the method, sample identity and limitations stated for the work.
What it contributes
Scope
Method selection
AAS commonly targets selected individual elements. ICP-OES can measure multiple selected elements during a multi-element run.
The appropriate technique depends on the sample matrix, expected concentration, required analytes, analytical procedure and reporting requirement—not on a claim that one instrument is always superior.
XRF provides rapid surface-region elemental information from a suitable item. AAS provides quantitative measurement from an appropriately prepared analytical sample.
Fire Assay is a precious-metal collection and separation procedure. AAS may be used as a measurement finish after suitable Fire Assay collection, so the two terms can describe different parts of one workflow.
Questions
AAS measures the concentration of a selected element in an appropriately prepared analytical sample by measuring characteristic light absorption.
It can determine gold when the preparation, concentration range, calibration and analytical procedure are suitable for the sample and intended result.
Yes. AAS is not a direct intact-bar scanner. The analytical portion must be prepared in a form appropriate to the confirmed procedure.
Yes, AAS can serve as an instrumental finish after an appropriate precious-metal collection procedure in certain analytical workflows.
AAS is commonly used for selected target elements, while ICP-OES can measure multiple selected elements in one analytical run. Method suitability depends on the specific sample and requirement.
Related services
Compare targeted AAS determination with quantitative multi-element analysis.
Review high-sensitivity trace-element measurement for suitable prepared samples.
Understand how an instrumental finish can relate to precious-metal collection.
Compare prepared-sample AAS with rapid, non-destructive surface screening.
Discuss the sample
Tell us the material, available sample quantity and the information the result needs to establish.
The final method and sample requirements are confirmed after the material and testing objective have been reviewed.